Showing results: 121 - 135 of 179 items found.
-
11853A -
Keysight Technologies
The Keysight 11853A accessory kit furnishes the RF components required for measurement of devices with 50-ohm, type-N connectors and when using a network analyzer with a type-N configuration. Each kit contains a type-N (female) short, a type-N (male) short, two type-N (male) barrels, two type-N (female) barrels, and a storage case.
-
CGT-7100 -
Shimadzu Corp.
The CGT-7100 analyzer measures the concentration of gases in a continuous way, using a ratio photometric non-dispersive infrared absorption (NDIR) method. All pretreatment parts required for measurement, such as the pump, filter, and electric dehumidifier, are built-in. The analyzer can measure three components including CO, CO2, or CH4 (any two of these) and O2, and is compatible with measurement at 100 vol%. The CGT-7100 has wireless communication capability, so measurement values and charts can be displayed on PCs or smart devices. And measurement data can be exported using a USB flash drive.
-
Model 7500ZA -
Teledyne Analytical Instruments
The 7500Z and 7600Z Series Infrared (IR) Analyzers are capable of detecting up to four chosen, individual IR absorbing components (i.e. CO, CO2, CH4, SO2, NO or NOX with external converter) on a continuous basis. Conveniently packaged in a 19” rack mount, the analyzer can also be supplied with an oxygen sensor, providing the operator with space saving, five in one, cost-effective design. The NEMA-4 enclosure can be purged to meet Class I, Div 1 (Zone 1) or Class I, Div 2 (Zone 2) hazardous area installation requirements.
-
Model 7600ZA -
Teledyne Analytical Instruments
The 7500Z and 7600Z Series Infrared (IR) Analyzers are capable of detecting up to four chosen, individual IR absorbing components (i.e. CO, CO2, CH4, SO2, NO or NOX with external converter) on a continuous basis. Conveniently packaged in a 19” rack mount, the analyzer can also be supplied with an oxygen sensor, providing the operator with space saving, five in one, cost-effective design. The NEMA-4 enclosure can be purged to meet Class I, Div 1 (Zone 1) or Class I, Div 2 (Zone 2) hazardous area installation requirements.
-
IGA Series -
Hiden Isochema Ltd
The IGA-001 is a dedicated single component gas sorption analyzer for the study of gas interactions with both solids and liquids. Incorporating an ultra-sensitive microbalance, the IGA-001 measures changes in sample mass as a function of temperature and pressure. The unique IGA method analyzes real time gravimetric data to determine kinetic parameters and simultaneously predict sorption equilibrium.
-
PG-300 Series -
HORIBA, Ltd.
The PG-300 is a compact and lightweight stack gas analyzer that can simultaneously measure up to five separate gas components. Its capability of providing precise measurement has been proven for field measurements and also for laboratory applications. The PG-300 series also offers the capability to measure methane (CH4). A 20% weight reduction over previous PG models and integration of shock-resistant side guards make the PG-300 a robust analyzer for use in the field. An optional electronic cooler unit is available for long-term measurements for severe monitoring applications as gas turbines, boilers, and incinerators PG-300 series versatility makes the analyzers suitable for investigating environmental problems, evaluating catalyst performance, and for controlling process gas streams.
-
Model CA-600 -
Teledyne Analytical Instruments
The CA600 is an online sequential sampling analyzer, using colorimetric methods. The analyzer can be configured to most laboratory colorimetric tests in individual processes.The CA600 Analyzers are easy to start up and use, simply connect the sample, waste and reagent lines and then power up the factory calibrated analyzer. Wall mount hardware is standard but an optional bench-top stand with reagent holder is also available. Accessing information for customizing an analysis routine is easily accomplished with the simple, user friendly menu structure and touch screen interface.The analyzer has two separated enclosures with two lockable doors. The top enclosure, called the electrical enclosure, includes the main power supply, the controller PCB assembly and the touchscreen interface. The bottom enclosure, called the liquids enclosure, includes all the components involved in the sample and reagent flow, mixing and reaction stages (sampling pump, reagent micro pumps and colorimetric reaction cell). Numerous analysis configurations can be programmed, depending on the accessories and the number of micro-pumps mounted in the liquid enclosure.
-
SolarWinds
One of the most important measurement tasks in radio engineering is the analysis of electrical circuits. A network analyzer is an instrument that is designed to solve this problem with high accuracy and efficiency. The circuits that can be analyzed with network analyzers have a wide range of applications ranging from simple devices such as filters and amplifiers to complex modules used in communications satellites. PLANAR specializes in the development and production of vector network analyzers that combine the capabilities of scalar network analyzers that measure not only the amplitude components of the main characteristics of the system (gain, loss, standing wave ratio, etc.), but also allow measurements of the amplitude and phase characteristics of the system .
-
Planar, llc
One of the most important measurement tasks in radio engineering is the analysis of electrical circuits. A network analyzer is an instrument that is designed to solve this problem with high accuracy and efficiency. The circuits that can be analyzed with network analyzers have a wide range of applications ranging from simple devices such as filters and amplifiers to complex modules used in communications satellites. PLANAR specializes in the development and production of vector network analyzers that combine the capabilities of scalar network analyzers that measure not only the amplitude components of the main characteristics of the system (gain, loss, standing wave ratio, etc.), but also allow measurements of the amplitude and phase characteristics of the system .
-
MKS Instruments
Our process monitors are innovative in-situ process monitoring instruments that are fully integrated, application-specific packages, including component residual gas analyzers (RGAs), analytical equipment, and control software. Process mass spectrometers are used in varied applications, including; Semiconductor, Thin Film (CVD, Etch, PVD and degas), pharmaceutical lyophylization and bulk gas purity monitoring.
-
Copper Mountain Technologies
Vector network analyzers are a valuable tool for radio technicians. VNAs allow you to tune frequency dependent components including transmitters, combiners and isolators, circulators, duplexers and filters. With a VNA you can measure and adjust S11 parameters, measure return loss, or analyze and fix response issues. CMT offers compact VNAs ideal for benchtop and field use.
-
MEXA-ONE IRLAM -
HORIBA, Ltd.
The MEXA-ONE IRLAM is an analyzer for the direct, simultaneous real-time measurement of the four relevant nitrogen-containing exhaust gas components NO, NO2, N2O and NH3.HORIBA's innovative infrared gas analysis technology, IRLAM™ (Infrared Laser Absorption Modulation), enables low-noise, high-precision measurement of four nitrogen compound gases (NO, NO2, N2O, NH3) in the low concentration range.
-
LT GasAnalyzer -
LT Gasetechnik
Highly performant analyzer for measuring the concentration of technical gases based on a thermal conductivity sensor, an infrared sensor a para magnetic sensor or combinations of these sensors. Sensors are precise, robust and have a low cross-sensitivity. Extractive online measurement of the concentration of flammable or non-flammable gas components in gas mixtures. Can measure trace oxygen (O2) levels in the parts per million (ppm) range.
-
ZNB -
Rohde & Schwarz GmbH & Co. KG
With frequency ranges of 9 kHz to 4.5/8.5 GHz and 100 kHz to 20/26.5/40/43.5 GHz, the network analyzers are designed for mobile radio, electronic goods as well as aerospace and defense applications, and can also be used in high speed printed circuit board design. The R&S®ZNB is ideal for developing, producing and servicing RF components such as amplifiers, mixers, filters and cables.
-
E4991B -
Keysight Technologies
The E4991B Impedance Analyzer has a frequency range of 1 MHz to 3 GHz. The E4991B provides 0.65% basic accuracy over a wide impedance range with a 40 V built-in DC bias source (Option 001). The equivalent circuit analysis function supports seven different multi-parameter models and helps you to simulate your own equivalent parameter values of components.